Open Watch signals in the test panel, select a gate on the canvas, then click Watch selected outputs. Apply a test input from the bench or a truth-table row. The timing trace shows the last 96 ticks, with the newest samples at the right.
Watch a useful set of signals
The watch list holds up to four signals. Start with the circuit’s final output and one intermediate gate on the path you suspect. Change an input or click the failing truth-table row to see how both signals respond. The intermediate signal helps narrow down where the response diverges.
Reproduce the same transition
Return the inputs to the same starting values before applying the failing row again. Read across the trace from the input change to the intermediate response and then the final output. Keeping the starting values consistent helps when comparing two runs. Use Clear to reset the trace before recording a new attempt.
Separate a late result from a wrong result
If the final output eventually reaches the expected value, compare when it settles with when the test sampled it. Inspect the longer path, including any packaged chip on it. If the signal settles at the wrong value, work upstream from the output instead. Look for the first gate whose settled value does not match the logic you intended.
Inspect a clocked circuit
Watch the clock with the data and output signals. Compare the output transition with the rising edge to see which data the circuit captured. This is especially useful when a register appears to change at the wrong time. Use Download CSV if you need to keep samples after the rolling window advances.